Target environment
- C9000 series switches
- IOS-XE 17.3.2 or later
Trouble case
- Symptoms: Ack import succeeds but Usage Reporting:
Last ACK received:
andNext ACK deadline:
are not updated- Cause/Solution: Investigating…
- Symptoms: Ack import fails with the following error
Import Data Failed
Could not validate trust chain
- Cause/Solution: The cause may be that the time setting of the device is out of sync. After correcting the device time to the correct time, importing the Ack may succeed.
- Symptoms: Ack import fails with the following error
Import Data Failed
Signature Verification Failed
- Cause/Solution: The following actions are required.
- Execute the
license smart factory reset
command - Reboot after saving settings with
write memory
- Delete the PI information of the corresponding device from CSSM
- Output the RUM report again from the device
- Import RUM report into CSSM and issue ACK
- Import ACK to applicable device
- Execute the